مقاله
|
Abstract
|
|
|
Title:
|
Unusual Metallic Foreign Body in Anterior Chamber; A Video Presentation
|
Author(s):
|
Mohammadreza Jafarinasab, MD; Hamidreza Hasani, MD
|
Presentation Type:
|
Oral
|
Subject:
|
Cornea and Anterior Segment
|
Others:
|
|
Presenting Author:
|
|
Name:
|
Hamid reza Hasani
|
Affiliation :(optional)
|
Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
|
E mail:
|
hamidrezahasani@yahoo.com
|
Phone:
|
02122550483
|
Mobile:
|
09121759054
|
|
|
Purpose:
|
To describe an interesting
case with unusual large metallic
foreign body in anterior
chamber.
|
Methods:
|
Case report: A 30-year-old
carpenter man presented with mild
blurred vision following working with
metallic and woody instruments.In
ocular exam a mild conjunctival
redness and a small object was
seen in anterior chamber(angle) in
slit lamp biomicroscopy. An orbital
CT scanning was performed to
evaluate the size and position of
foreign body.other ophthalmic
exams were normal.
|
Results:
|
He underwent a
surgery under general anesthesia to
remove the foreign body which was
much more larger than it was seen
in slit lamp biomicroscopy.
|
Conclusion:
|
It is recommended to be
careful in ocular exam not to miss a
large unusual inta-ocular foreign
body.
|