Title: Aberration and Topometric Indices of 65 Ectatic and Irregular Corneas With RGP Contact Lenses
Author(s): Ghandehari- Motlagh.M, Mirjalili.N, Akbari.M
Presentation Type: Poster
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Mohammad Ghandehari-Motlagh
Affiliation :(optional) 1.Isfahan University of Medical Sciences (Feiz Hospital), Isfahan-Iran 2.Sadra Eye Surgery Center, Isfahan-Iran
E mail: oculist233@aol.com
Phone: 03116689608
Mobile: 09132000891
Purpose:

To evaluate of the effect of an ideal fit of RGPs on HOA and keratoconus indices and its effect on psychological patient’s durability of RGP.

Methods:

In this cohort study,65 keratoconus eyes with more than 3 lines(Snellen)improvement between BSCVA and BCVA(RGP)were imaged with Pentacam and their topometric and Zernike analysis findings without RGP were recorded. After 6 months or later of RGP fitting(Rose-K,Boston XO2),imaging with pentacam was repeated and the above information were recorded.

Results:

65 different grades of keratoconus eyes with mean age of 27.32 +_ 5.51 yrs/old enrolled including M 28(43.1%)and F 37(56.9%) . 44(67.7%)with family Hx of Kc and 21(31.25%)without any Kc in their families.54(83.1%) with and 11(16.9%) without any ocular allergy Hx .Maximum percent of age of onset of kc was 15 ys/old(29.2%).This study showed there are meaningful correlations between Pentacam indices and HOA in each grade of Kc with and without RGP .92.3% of patients had foreign body sensation but 96.9% had 11-20 hours/day RGP wear that confirms on psychologic effect of an ideal fit on patient’s motivation.

Conclusion:

With regard of the three points touch principle of RGP fitting in Kc corneas ,the patients will have a decrease in HOA and improvement of RGP durability and so delayed need for PK or LK .

Attachment: 621Poster.pptx





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        ارسال مقالات
        برنامه کنگره
        برنامه های جانبی
        نمایشگاه
        تماس با ما
        آرشیو کنگره سالهای گذشته
        جستجوی سخنران
 
Last News

  - بـیــست و سومین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران