مقاله
|
Abstract
|
|
|
Title:
|
One Year Results of Keraring SI6 Model in Early and Moderate Keratoconus
|
Author(s):
|
Hassan Hashemi, Kazem Amanzadeh
|
Presentation Type:
|
Oral
|
Subject:
|
Cornea and Anterior Segment
|
Others:
|
|
Presenting Author:
|
|
Name:
|
Hassan Hashemi
|
Affiliation :(optional)
|
Noor ophthalmology research center, Noor Eye Hospital, Tehran, Iran
|
E mail:
|
info@irsocongress.org
|
Phone:
|
0
|
Mobile:
|
09121127421
|
|
|
Purpose:
|
To evaluate visual, Refractive and corneal topographic outcomes after Implantation of Keraring in Eyes with early to moderate Keratoconus.
|
Methods:
|
This Case Series study is comprised of 200 eyes with grade 1 to 4 Keratoconus that had Keraring SI6 implantation using femtosecond technology (ALCON-fs-200 and LDVZ6) Visual, refractive and corneal topography outcomes were reported after one years follow-up.
|
Results:
|
The mean preoperative uncorrected visual acuity (UCVA) for all Eyes was 0.25 snellen line, and improved to 0.51 after one year (P-value <0.05). The mean preoperative BSCVA for all eyes was 0.40 snellen line, and improved to 0.63 at one year (P-value<0.05). There was a significant reduction in spherical Equivalent error from -3.5 to -0.97 D (P-value<0.05) and decrease in preoperative K-Max from 50.02 to 46.65 D postoperatively. (P-value<0.05) The Mean refractive cylinder decreased from 3.40 to 0.87 D postoperative (P-Value<0.05).
|
Conclusion:
|
After one year follow-up Keraring Implantation using femtosecond Laser is effective for the treatment of Keratoconus and provides safe and acceptable visual outcomes.
|